Determining the Accuracy of Urine Volume Calculations made by Stationary 2D B-Mode Ultrasonography

Nonfiction, Health & Well Being, Medical, Specialties, Radiology & Nuclear Medicine
Cover of the book Determining the Accuracy of Urine Volume Calculations made by Stationary 2D B-Mode Ultrasonography by Muhammad Shoyab, GRIN Verlag
View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart
Author: Muhammad Shoyab ISBN: 9783656894186
Publisher: GRIN Verlag Publication: February 10, 2015
Imprint: GRIN Verlag Language: English
Author: Muhammad Shoyab
ISBN: 9783656894186
Publisher: GRIN Verlag
Publication: February 10, 2015
Imprint: GRIN Verlag
Language: English

Research Paper (postgraduate) from the year 2014 in the subject Medicine - Radiology, Nuclear Medicine, grade: A, , language: English, abstract: This study was the first of its kind in that it fills the gap in the scientific data created by the absence of any investigation making a direct comparison between 2D-sonograhpic and true urine volumes. While most hospitals in the developed world now prefer to measure urine volumes with portable bladder scanners and 3D ultrasound devices, none of these technology are widely available in Bangladesh and other developing countries. Nonetheless, hundreds to thousands of ultrasound examinations involving the measurement of maximum cystometric capacity (MCC) and postvoid residue (PVR) of urinary bladder are done with 2D stationary ultrasound every day. Despite our clinical experience that these measurements are quite accurate and reliable, it was deemed essential to establish scientific evidence in its favour. This observational study was done in the Dept of Radiology & Imaging at Bangabandhu Sheikh Mujib Medical University (BSMMU), Dhaka, Bangladesh, during the period July - December 2014. 384 adult patients who came to BSMMU for ultrasound examinations were enrolled in this study and their true urine volumes were compared against that calculated using 2D B-mode ultrasound. The findings were analysed using two statistical approaches - correlation coefficient and limits of agreement. Calculation of the correlation coefficient was done so that the findings of this study could be compared with other relevant studies, most of which have used the correlation coefficient to assess the accuracy of the ultrasound equipment (3D or portable). However, Bland & Altman's limits of agreement method is the standard statistical approach to assess agreement between two methods of clinical measurement, as determined by The Statistician, The Lancet and others. Findings of this study show that bladder urine volumes measured by 2D B-mode ultrasound had high correlation (r = 0.96, 95% CI 0.955 - 0.969, P < 0.0001) and agreement (96.35%, LoA : -7.84 ± 53.05 mL) with true urine volumes. Sonographic urine volumes were accurate in both males and females, of all adult age groups and at all volume ranges including <100 mL.

View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart

Research Paper (postgraduate) from the year 2014 in the subject Medicine - Radiology, Nuclear Medicine, grade: A, , language: English, abstract: This study was the first of its kind in that it fills the gap in the scientific data created by the absence of any investigation making a direct comparison between 2D-sonograhpic and true urine volumes. While most hospitals in the developed world now prefer to measure urine volumes with portable bladder scanners and 3D ultrasound devices, none of these technology are widely available in Bangladesh and other developing countries. Nonetheless, hundreds to thousands of ultrasound examinations involving the measurement of maximum cystometric capacity (MCC) and postvoid residue (PVR) of urinary bladder are done with 2D stationary ultrasound every day. Despite our clinical experience that these measurements are quite accurate and reliable, it was deemed essential to establish scientific evidence in its favour. This observational study was done in the Dept of Radiology & Imaging at Bangabandhu Sheikh Mujib Medical University (BSMMU), Dhaka, Bangladesh, during the period July - December 2014. 384 adult patients who came to BSMMU for ultrasound examinations were enrolled in this study and their true urine volumes were compared against that calculated using 2D B-mode ultrasound. The findings were analysed using two statistical approaches - correlation coefficient and limits of agreement. Calculation of the correlation coefficient was done so that the findings of this study could be compared with other relevant studies, most of which have used the correlation coefficient to assess the accuracy of the ultrasound equipment (3D or portable). However, Bland & Altman's limits of agreement method is the standard statistical approach to assess agreement between two methods of clinical measurement, as determined by The Statistician, The Lancet and others. Findings of this study show that bladder urine volumes measured by 2D B-mode ultrasound had high correlation (r = 0.96, 95% CI 0.955 - 0.969, P < 0.0001) and agreement (96.35%, LoA : -7.84 ± 53.05 mL) with true urine volumes. Sonographic urine volumes were accurate in both males and females, of all adult age groups and at all volume ranges including <100 mL.

More books from GRIN Verlag

Cover of the book Entwicklung von Mediaplänen unter Berücksichtigung von Wearout Effekten by Muhammad Shoyab
Cover of the book Singles und ihre sozialen Netzwerke by Muhammad Shoyab
Cover of the book Die Linke. Sozialistischer Deutscher Studentenbund by Muhammad Shoyab
Cover of the book Machiavelli pur. Der Principe by Muhammad Shoyab
Cover of the book Unterrichtseinheit: Erstellung eines Regenstabs (6. Klasse) by Muhammad Shoyab
Cover of the book Selbstgesteuertes Lernen als Herausforderung für die Didaktik by Muhammad Shoyab
Cover of the book Veränderte Kindheit. Wie Erwachsene mit Veränderungen in der Lebenswelt der Kinder umgehen können by Muhammad Shoyab
Cover of the book Die Lernende betriebliche Organisation by Muhammad Shoyab
Cover of the book (Analytische und statistische) Verfahren der Kostenplanung: Gegenüberstellung und Beurteilung aus der Sicht des Controlling by Muhammad Shoyab
Cover of the book Frühförderung. Die heilpädagogische Übungsbehandlung nach von Oy und Sagi by Muhammad Shoyab
Cover of the book Das Kurt-Eisner-Denkmal in der Kardinal-Faulhaber-Straße in München by Muhammad Shoyab
Cover of the book Erarbeitung der Flächeninhaltsformel des Rechtecks durch Auslegen mit Einheitsquadraten by Muhammad Shoyab
Cover of the book Mittelständische Strukturen als Leitbild für Großunternehmungen by Muhammad Shoyab
Cover of the book Der römische Senat unter den Kaisern Claudius und Nero by Muhammad Shoyab
Cover of the book Der homo oeconomicus in Bezug auf verkehrspolitische Engpässe am Beispiel der 'Billig-Flüge' unter Berücksichtigung der Theorie Joseph Schumpeters by Muhammad Shoyab
We use our own "cookies" and third party cookies to improve services and to see statistical information. By using this website, you agree to our Privacy Policy