Single and Multiple Stimulus Static Perimetry in Glaucoma; The Two Phases of Perimetry

The Two Phases of Perimetry

Nonfiction, Health & Well Being, Medical, Specialties, Ophthalmology
Cover of the book Single and Multiple Stimulus Static Perimetry in Glaucoma; The Two Phases of Perimetry by E.L. Greve, Springer Netherlands
View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart
Author: E.L. Greve ISBN: 9789401177658
Publisher: Springer Netherlands Publication: December 6, 2012
Imprint: Springer Language: English
Author: E.L. Greve
ISBN: 9789401177658
Publisher: Springer Netherlands
Publication: December 6, 2012
Imprint: Springer
Language: English

does not vary more than 1 % over the whole surface. Stimulus: The luminance of the stimuli can be regulated by means of neutral density filters. These filters are neither entirely neutral nor completely uniform, but these variations are not significant for perimetry. The maximum luminance of the stimuli is standardized at 1000 asb (316 2 cd.m-). The standard GP for kinetic perimetry has 3 neutral density filters which reduce the luminance by 0.5, 1.0 and 1.5 log units respectively. The modification of the GP for static perimetry is supplied with an additional series of four neutral density filters, which allow luminance steps of 0.1, 0.2, 0.3 and 0.4 log units. The resulting luminance values, expressed in apostilb, are given in Table I. TABLE I Luminance values of the Goldmann perimeter 4 3 2 steps lux 1430 450 143 45 3,1 asb 1000 315 100 31,5 3,1 2 cd/m 315 100 31,5 10 3,1 ßL ±30 10 3 3,1 L log L asb 3 2,5 2 2 1,5 0,5 2 Background: 31,5 asb. = 10 cd/m • Coefficient of reflection 0,7. 1 2 (1 asb = -cd/m).

View on Amazon View on AbeBooks View on Kobo View on B.Depository View on eBay View on Walmart

does not vary more than 1 % over the whole surface. Stimulus: The luminance of the stimuli can be regulated by means of neutral density filters. These filters are neither entirely neutral nor completely uniform, but these variations are not significant for perimetry. The maximum luminance of the stimuli is standardized at 1000 asb (316 2 cd.m-). The standard GP for kinetic perimetry has 3 neutral density filters which reduce the luminance by 0.5, 1.0 and 1.5 log units respectively. The modification of the GP for static perimetry is supplied with an additional series of four neutral density filters, which allow luminance steps of 0.1, 0.2, 0.3 and 0.4 log units. The resulting luminance values, expressed in apostilb, are given in Table I. TABLE I Luminance values of the Goldmann perimeter 4 3 2 steps lux 1430 450 143 45 3,1 asb 1000 315 100 31,5 3,1 2 cd/m 315 100 31,5 10 3,1 ßL ±30 10 3 3,1 L log L asb 3 2,5 2 2 1,5 0,5 2 Background: 31,5 asb. = 10 cd/m • Coefficient of reflection 0,7. 1 2 (1 asb = -cd/m).

More books from Springer Netherlands

Cover of the book Rangeland Stewardship in Central Asia by E.L. Greve
Cover of the book The Uses of Antiquity by E.L. Greve
Cover of the book Design and Production of Multimedia and Simulation-based Learning Material by E.L. Greve
Cover of the book The Invention of Physical Science by E.L. Greve
Cover of the book Molecular Diagnostics: Promises and Possibilities by E.L. Greve
Cover of the book Molecular Techniques in Crop Improvement by E.L. Greve
Cover of the book Drinking Water Treatment by E.L. Greve
Cover of the book Atlas of Bone Marrow Pathology by E.L. Greve
Cover of the book Illustrated Encyclopedia of Dermatology by E.L. Greve
Cover of the book The Biology of Rarity by E.L. Greve
Cover of the book Satellite-based Applications on Climate Change by E.L. Greve
Cover of the book The Cult of Authority by E.L. Greve
Cover of the book Character, Liberty and Law by E.L. Greve
Cover of the book Spatial Microsimulation: A Reference Guide for Users by E.L. Greve
Cover of the book Earthquake Disasters in Latin America by E.L. Greve
We use our own "cookies" and third party cookies to improve services and to see statistical information. By using this website, you agree to our Privacy Policy